| Abstract | This research was to modify
charcoal /R11 4 (Dchloro Tetraflouro
and run t h e
Ethane > so lid
activated
adsorption
refrigerator , which was originally designed and constructed by
Dr. R.E. Critoph at Warwick University.
The collector of there frigerated has an area of 1 m2 a nd
is fill e d with 24. 2 k g of coconut based activate d charcoal
(G r ad e 2 0 7Cl in t h e collector tubes. The performance of t h e
solar refrigerator for selected clear and cloudy days is
presented in this report . Test results showed that the system
can not produce ice . The minimum evaporator temperature
recorded was about 1 4 ° C, and the experimentally observed overall solar COP value was 0.014. |